STATE CHEMICAL MFG CO -- GREASE B GONE -- 7930-01-389-1374
===================== Product Identification =====================
Product ID:GREASE B GONE
MSDS Date:02/01/1993
FSC:7930
NIIN:01-389-1374
=== Responsible Party ===
Company Name:STATE CHEMICAL MFG CO
Address:3100 HAMILTON AVE
City:CLEVELAND
State:OH
ZIP:44114-3701
Country:US
Info Phone Num:216-861-7114
Emergency Phone Num:216-861-7114
CAGE:53798
=== Contractor Identification ===
Company Name:STATE CHEMICAL MANUFACTURING CO.
Address:3100 HAMILTON AVENUE
Box:City:CLEVELAND
State:OH
ZIP:44114-3701
Country:US
Phone:216-861-7114
CAGE:53798
============= Composition/Information on Ingredients =============
Ingred Name:A NATURAL (TERPENE-TYPE) CITRUS OIL (CONTAINING EITHER ING
2 OR 3)
RTECS #:9999999ZZ
Fraction by Wt: >80%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ORANGE OIL TERPENES
CAS:68917-57-7
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ORANGE OIL, TERPENES
CAS:68647-72-3
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:OTHER PROT EQPT: DESIGN CRITERIA
RTECS #:9999999ZZ
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE EYE IRRITATION.
PROLONGED SKIN CONTACT MAY CAUSE DRYNESS AND CHAPPING. CHRONIC: NO
ADVERSE EFFECTS EXPECTED.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PRE-EXISTING
SENSITIVITIES-ESPECIALLY TO CITRUS PRODUCTS ASTHMA, SINUS
IRRITATIONS AND OTHER RESPIRATORY TRACT IRRITATIONS OR INFECTIONS.
======================= First Aid Measures =======================
First Aid:INGEST: CALL A PHYSICIAN OR POISON CONTROL CENTER
IMMEDIATELY. INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
O*2/ARTIFICIAL RESPIRATION) . EYES: FLUSH EYES IMMEDIATELY WITH
PLENTY OF COOL WATER FOR AT LEAST 15 MINUTES. IF IRRITATION
PERSISTS, CALL A PHYSICIAN. SKIN: FLUSH WITH WATER, WASH WITH SOAP
AND WATER.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>120F,>49C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, OR FOAM
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:USE ABSORBENT MATERIAL. FLUSH RESIDUE WITH
WATER. DISPOSE OF PROPERLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL PLACE, OUT OF DIRECT
SUNLIGHT. DO NOT REUSE EMPTY CNTNRS. RETURN EMPTY DRUMS TO A DRUM
RECNDTNER/DESTROY BY CRUSHING.
Other Precautions:READ & FOLLOW ALL LBL DIRECTIONS & PRECS BEFORE USING
PROD. THESE PRODS ARE INTENDED FOR INDUS & INSTITUTIONAL USE
ONLY.DO NOT STORE NEAR FOOD TO PVNT ACCIDENTAL INGEST. CAUT:
COMBUST. KEEP AWAY FROM HEAT & OPEN FLAME. AVOID EYE (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NORMAL VENTILATION.
Protective Gloves:RUBBER GLOVES ARE RECOMMENDED.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYEWASH STATION OR CLEAN WATER SOURCE IN
CASE OF ACCIDENTAL EYE CONTACT. (MFR). EYE WASH DEVICE MEETING ANSI
(ING 4)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: 100 (WT). OTHER PREC: CONT. DO NOT TAKE INTERNALLY. NOTE:
BECAUSE GREASE B GONE IS POWERFUL ORG CMPD, IT MAY HARM SOME
PLASTIC/PAINTED SURFS. TEST FIRST BEFORE APPLYING. SINCE THIS PROD
IS EX CELLENT GREASE SOLV IT WILL EFTIVELY DEFAT SKIN. NOT FOR
HOUSEHOLD USE/RESALE. KEEP OUT OF REACH OF CHILDREN.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:221F,105C
Spec Gravity:0.845
Solubility in Water:EMULSIFIABLE
Appearance and Odor:A CLEAR PALE YELLOW LIQUID WITH CITRUS ODOR.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
VIOLENT REACTION WITH (IF*2 + TETRAFLUOROETHYLENE) OXIDIZING MATERIALS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME.
Hazardous Decomposition Products:NONE
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF AS AN IGNITABLE WASTE. FOLLOW ALL
FEDERAL, STATE AND LOCAL REGULATIONS REGARDING WASTE DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.